dpt sensor

Brief Introduction

The model 3351 is a capacitive differential pressure transducer with all welded stainless steel construction. differential pressure sensor is integrated inside the 3351.

Different types of fill fluid are available for this model for different applications. The fill fluid can be the standard type-A fluid for common industry of general purpose, the type-B fluid suitable for oxygen industry, or the type-C fluid suitable for tobacco industry.


Features

  • Stability:0.2%/Year

  • Range:250pF ±20PF

  • Zero:130pF ±20PF

  • Accuracy:Nominal Range 0.1%

  • Model Number:AT3051

  • Process Temperature Range:-40 to 104°c
  • Stability:0.2%/Year

  • Fill Fluid:Silicone /Fluorine Oil

  • Wiring System:3-Wire,5-Wire

  • Housing Material:316SS

  • Overpressure Limit:AP GP 13.8Mpa DR DP HP

Performance

ItemParameters
Accuracy±0.1%
Stability±0.2% (12 months)
Temperature Range-40℃ ~ +140℃


Temperature Affect

Zero Error: ±0.25% / 55℃
Range Error: ±0.5% / 55℃
Static Pressure DP 13.8MPa          HP 25MPa          DR 6.9MPa
Overpressure LimitAP GP 13.8MPa          DR DP HP
Diaphragm Material316Lss         Hastelloy C          Tant Alum
ModelStabilityTemp LimitPressure LimitRange
AT3051DP±0 . 1 %UR L-40~140 13.79MPa1.3~6890KPa
AT3051GP±0 . 1 %UR L-40~140 13.79MPa1.3~41370KPa
AT3051DR±0 . 2 %UR L-40~140 6.9MPa0.125~1.5KPa
AT3051HP±0 . 1 %UR L-40~140 31.02MPa6.2~2068KPa
AT3051AP±0 . 1 %UR L-40~140 13.79MPa6.2~6890KPa
AT3051LT±0 . 2 %UR L-40~140 
635~70380mmH2O
AT3051DP±0 . 1 %UR L-40~140 13.79MPa635~6895KPa
AT3051GP±0 . 1 %UR L-40~149 51.71MPa635~6895KPa
AT1151DP±0 . 1 %UR L-40~140 13.79MPa1.3~6890KPa
AT1151GP±0 . 1 %UR L-40~140 51.71MPa1.3~41370KPa
AT1151DR±0 . 2 %UR L-40~140 6.9MPa0.125~1.5KPa
AT1151HP±0 . 1 %UR L-40~140 31.02MPa6.2~6890KPa
AT1151AP±0 . 1 %UR L-40~140 13.79MPa6.2~6890KPa
AT1151LT±0 . 1 %UR L-40~140 
635~70380mmH2O
AT1151DP±0 . 1 %UR L-40~140 13.79MPa6.2~6890KPa
AT1151GP±0 . 1 %UR L-40~140 13.79MPa6.2~6890KPa
AT2088±0 . 5 %UR L-40~120 
-0.1~40KPa
SP±0 . 5 %UR L-20~80 
-0.1~40MPa
SH-A±0 . 5 %UR L-20~80 
0~200m



Package & Delivery

dp pressure sensor

diff pressure sensor


The medium pressure is transferred to the test diaphragm in the middle of δ room by the barrier diaphragm and Silicon oil, As the test diaphragm is a tight flexible element, it produces displacement following the pressure differential.
The displacement of the diaphragm and pressure differential are in direction proportion, the max displacement is 0.1mm, It is tested by the capacitive plate on both sides, Then the differential capacitor between the test diaphragm and capacitive board is switched to standard output by the Circuit Current.
For a better browsing experience, we recommend that you use Chrome, Firefox, Safari and Edge browsers.